Specifications
2–2 975-0639-01-01 Rev A
This guide for use by qualified personnel only
Inverter Specifications
NOTE: All inverter specifications are at nominal conditions: ambient temperature
of 77 °F (25 °C), 24 VDC, unless otherwise specified.
AC Output SW 2524 120/240 SW 4024 120/240
Output waveform true sine wave true sine wave
Continuous output power (AC)
- Maximum
- 30 minutes
2500 W
2700 W
a
a.2700 W for 30 minutes, 0 W for 30 minutes.
3400 W
4000 W
b
b.4000 W for 30 minutes, 0 W for 30 minutes.
Maximum continuous output current 11 A 15 A
Surge power rating (5 seconds) 5000 W
c
c.5000 W for 5 seconds, 2500 W for 300 seconds.
7000 W
d
d.7000 W for 5 seconds, 3500 W for 300 seconds.
Inverter peak output current 24.3 A 41 A
AC OUTPUT connection Split-phase (L1/L2) Split-phase (L1/L2)
Peak efficiency 91.5% 92%
Output power factor
(capacitive or inductive)
0 to 1 0 to 1
Operating voltage range
single-phase/split-phase
104/208 VAC to
127/254 VAC
104/208 VAC to
127/254 VAC
Nominal voltage
single-phase/split-phase
120/240 VAC 120/240 VAC
Operating frequency range selectable
50 or 60 Hz
selectable
50 or 60 Hz
Default output frequency 60 Hz 60 Hz
DC Input SW 2524 120/240 SW 4024 120/240
Voltage range 20–34 VDC 20–34 VDC
Maximum continuous power voltage
range
22–27 VDC 22–28 VDC
Maximum battery current 150 A 230 A
No-load power draw (Inverter On) 38 W 40 W
Low battery voltage shutdown cut-off
(other values selectable)
21.0 V (default) 21.0 V (default)
High battery voltage shutdown cut-off
(other values selectable)
33.0 V (default) 33.0 V (default)
ConextSW-NA-InstallationGuide.book Page 2 Thursday, December 20, 2012 2:05 PM