AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes
PN 613-001136 Rev. B 4 Allied Telesis Inc.
If you plan to add a redundant AT-CV5M02 Management Card to the AT-CV5000 Chassis, do not add
it until after you’ve updated all the cards. If there is a redundant AT-CV5M02 Management Card in the
chassis, remove it until you’ve completed the upgrade procedure.
This procedure requires a terminal or a personal computer with a terminal emulator program that can
handle lines of up to 125 characters.
This procedure assumes you have already obtained the Version 4.0.1 image files of the AT-S73 and
AT-S99 Management Software from Allied Telesis and stored them on your TFTP server.
Upgrading one local or remote line card takes approximately three minutes using TFTP or four minutes
using XMODEM at a baud rate of 115200 bps on the Console port.
Upgrading the AT-CV5M02 Management Card takes approximately two minutes using TFTP or four
minutes using XMODEM at a baud rate of 115200 bps on the Console port.
If the AT-S73 Management Software on the AT-CM2 and AT-CM70S Line Cards is earlier than Version
3.0.0, or if you are uncertain as to the version numbers of their management software programs, refer
to “Upgrading Versions Earlier than Version 3.0.0” on page 12.
To avoid possible compatibility issues between the AT-CV5M02 Management Card and the media
converter line cards in a chassis, all the cards should have the same versions of their respective
management software programs. For example, if the management card has Version 4.0.1, then the
AT-CM2 and AT-CM70S Line Cards should have Version 4.0.1 of the AT-S73 Management Software.
As explained in the following procedures, you can use the OAM-based remote peer management
feature to update remote AT-CM2 and AT-CM70S Line Cards that have Version 2.0.2 or later of the
AT-S73 Management Software. To update remote line cards that are not configured for this feature or
whose enclosures do not contain management cards, you’ll have to visit the remote sites.
This release does not include a new bootloader file for the AT-CM2 and AT-CM70S Line Cards. This
release should be used with bootloader version 1.7.0.
The new AT-CM301, AT-CM302 and AT-CM3K0S Media Converter Line Cards do not need to be
upgraded because they ship with Version 4.0.1 of the AT-S102 Management Software.
When instructed to enter a value for a parameter, select the parameter with the up or down arrow keys
on your keyboard and press Return. When the “->” prompt is displayed, enter the value for the
parameter.
CAUTION:
The media converter line cards stop forwarding network traffic during the upgrade procedure. If the line
cards are part of a live network, you should perform the procedure during a period of low network activity to
minimize the impact to your network users.
This procedure consists of the following phases:
“Phase 1: Installing the AT-CV5M02 Management Card” on page 5
“Phase 2: Starting a Local Management Session” on page 5
“Phase 3: Displaying the Version Numbers of the Management Software” on page 5
“Phase 4: Assigning an IP Address Configuration” on page 6
“Phase 5: Configuring the TFTP Client” on page 7
“Phase 6: Upgrading the AT-S73 Management Software on the AT-CM2 and AT-CM70S Line Cards to
Version 4.0.1” on page 8