Contax SW II - REV 4.01 Betriebsanweisung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
AT-S73, AT-S99 and AT-S102 Version 4.0.1 Software Release Notes
PN 613-001136 Rev. B 5 Allied Telesis Inc.
“Phase 7: Upgrading the AT-S99 Management Software on the AT-CV5M02 Management Card to
Version 4.0.1” on page 11
If you encounter a problem, refer to “Troubleshooting the Upgrade Procedure” on page 11.
Phase 1: Installing the AT-CV5M02 Management Card
If the AT-CV5M02 Management Card is new, install the card with these steps:
1. If the chassis contains the AT-CV5M01 Management Card, remove the card from the chassis.
Note:
You cannot use the AT-CV5M01 Management Card to monitor or manage media converter line cards
that have Version 4.0.1 of the AT-S73 Management Software.
2. Install the AT-CV5M02 Management Card. For instructions, refer to the Installation Guide included
with the card. The card, which supports hot-swapping, can be installed while the chassis is powered
on.
3. Wait approximately one minute for the AT-CV5M02 Management Card to initialize its AT-S99
Management Software. The card is ready when its RDY LED is on.
4. Since the management card will need to communicate with your TFTP server, connect its 10/100Base-
TX port to a device on your network, such as an Fast Ethernet switch. The port, which has a fixed
wiring configuration of MDI, sets its speed and duplex mode with Auto-Negotiation.
Phase 2: Starting a Local Management Session
To start a local management session on the Console port of the AT-CV5M02 Management Card:
1. Connect the management cable that ships with the management card to the Console port on the
management card and to an RS-232 port on a terminal or a personal computer with a terminal
emulator program.
2. Configure the terminal of terminal emulator program to the following settings:
Bits per second: 115200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
3. Press the Return key to display the login prompt.
4. Enter “manager” for the username.
5. When prompted for the password, enter the password. If the management card is new, the default
password is “friend.” The management software displays the Main Menu. Go to the next procedure to
determine the version numbers of the management software programs currently installed on the
AT-CV5M02 Management Card and the AT-CM2 and AT-CM70S Media Converter Line Cards.
Phase 3: Displaying the Version Numbers of the Management Software
Before you begin to update the cards with the new management software, it is important to determine the
version numbers of their current management software programs. Cards that contain Version 3.0.0 or
4.0.0 can be upgraded directly to Version 4.0.1. Line cards with Version 2.0.2 or earlier have to be
upgraded first to Version 3.0.0. To view the version numbers of the management software programs on the
management card and the AT-CM2 and AT-CM70S Line Cards:
1. From the Main Menu, select Module Status and Configuration.
Seitenansicht 4
1 2 3 4 5 6 7 8 9 10 ... 16 17

Kommentare zu diesen Handbüchern

Keine Kommentare